Technical Specs
LIGHTING SYSTEM
Control Board
- ETC Express 48/96
- Computerized lightboard with memory
- 24 fully programmable submasters
Dimmers
- (2) DMX512 model CD-80 dimmer racks each with 96 dimmer modules (2.4kW)
Fixtures
- (18) ETC Source Four 19 degree
- (6) ETC Source Four 26 degree
- (18) ETC Source Four 36 degree
- (5) ETC Source Four 50 degree
- (24) Strand 6” Fresnels (1K)
- (8) Strand 8” Fresnels (1K)
- (7) Altman 3 Cell Cycs (1k)
- (8) Strand Scoops (1k
)
- Altman Explorer Followspot located in Light Booth
- Altman Voyager Followspot located in Light Booth
Circuits
- (30) Front of House Cove
- (9) Left and Right Front of House Torms (Internally Paired)
- (29) First Electric
- (9) Drop Box
- (12) Second Electric
- (9) First Strip on Drop Box
- (12) Third Electric)
- (9) Second Strip on Drop Box
- (12) Fourth Electric
- (9) Third Strip on Drop Box
- (12) Fifth Electric
- (2) Stage Left and Right Proscenium Pockets (Internally Paired)
- (2) Off Down Stage Left and Right Floor Pockets (Internally Paired)
- (2) Off Mid Stage Left and Right Floor Pockets (Internally Paired)
- (2) Off Up Stage Left and Right Floor Pockets (Internally Paired)
- (4) Up Stage Left Floor Pockets
- (4) Up Stage Mid Left Floor Pockets
- (4) Up Stage Mid Right Floor Pockets
- (4) Up Stage Right Floor Pockets
All Circuits and Instruments are standard stage pin connectors
Standard House Plot Lightwrite available upon request
Communications
Two Channel hardwired HME PS731 Intercom system with
- (5) 501 ClearCom Beltpacks
- (4) RS601 ClearCom Beltpacks
- (10) Single Muff Headsets
Power
- 200 amp 3 phase tie-in disconnect Stage Right and Stage Left (Internally Paired)
- 200 amp 3 phase tie-in disconnect Up Stage Right in outside hallway (100 feet from Down Stage Right Plaster Line)
Audio System :
Mixer
- Allen & Heath GL2200 – 32 channel mixer
Cluster Speaker Processing
- DBX 160X mono compressor/limiter
- White 4400 1/3 octave graphic equalizer
- Ashly XR70/12 crossover
- Crown PS 200 powering upper cluster horns
- Crown PS 200 powering lower cluster horns
- QSC 1450 powering low frequency enclosure
Proscenium Speaker Processing
- Ashly XR20/12 crossover Stage Left Cabinet
- Ashly XR20/12 crossover Stage Right Cabinet
- UREI 6230 powering horns
- UREI 6260 powering low frequency speakers
Auxiliary Processing
- (2) Yamaha Q2031 stereo 1/3 octave equalizer
- UREI 562 Feedback Suppressor
- Yamaha REV7 digital reverb
- Nakamichi MRII cassette deck
- Tascam CD-RW900 CD player
Main Speaker System
A central cluster is mounted directly over the front of the stage. It features:
- (2) JBL 23360A (90×40) horns with JBL 2445 (2-inch) drivers
- (2) JBL 2365A (60×40) horns with JBL 2445 (2-inch) drivers
- (2) JBL 4507 in low frequency enclosure
Located in the Proscenium Left and Right:
- Cabinet on each side with (1) JBL 4518 speaker and (1)JBL 2441 horn
Monitor System
- (4) JBL Caberat cabinets with (2) 10 inch speakers and (1) horn
- (1) Crown PS 400 stereo amplifier
- (1) QSC 1450 stereo amplifier
Microphones
- (4) Crown PCC 160
- (2) Shure SM58
- (2) Shure SM 58 Beta
- (2) Shure ULX/S Stanard Wireless Systems
- (2) AKG 320B
- (2) AKG C535EB
Paging System
- A backstage paging system, for pages and program feed, is available from Off Down Stage Left. Speakers are located in each dressing room, the Green Room, and the dressing room hallway.
General Information:
Seating Capacity
1924 total seats
868 front orchestra
591 rear orchestra
465 balcony
Accessible Seating
Curtains
Main Act Curtain
Mid Stage Traveller
Concert Traveller
Upstage Cyclorama
6 Paris Leg Curtain
6 Border Curtains
Pipes
43 lines
Pit
520 square feet
Stage
Size – 4,185 square feet
45 feet deep, 93 feet wide
Proscenium width – 50 feet
Opening – 50 feet wide, 28 feet high
Floor, Maple
Rooms
4 solo dressing rooms
2 chorus rooms
1 Green Room
1 Reception Room
Loading
Two docks, truck height, stage level
Parking
Free
Box Office
Ticketing – Ticketmaster
Telephone: (757)393-5144